On the day of a scheduled inspection, customers can call the City of Tracy at 209-831-6400 any time after 8:00 a.m.  The City of Tracy will then give you the assigned inspector’s name and cell phone number.  Customers can then contact the inspector to get an estimated timeframe as to when the inspector will arrive for the inspection.

 
Permit No. 18-1886 Permit Type   ACCESSORY BLDG Site Address   TRACY HILLS PUBLIC PARK # 1
Applied   08/09/2018 Applicant   JOHN PALMER
Approved   03/19/2019 Owner   TRACY PHASE 1, LLC
Issued   03/19/2019 Contractor   THE PUBLIC RESTROOM COMPANY
Parent Permit No.   Description   TRACY HILLS PUBLIC PARK # 1 - RESTROOM/STORAGE BLDG
  Notes   (3/18/2019 1:53 PM CRL) RCPT#4080-0034
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/19/2019010-UNDERGROUND PLUMSHAIN NIVENAPPROVED3/19/2019 12:00:00 AM Sewer and main water service connection has not been completed. Underground plumbing approved at slab location only.

 10/16/2018010-UNDERGROUND PLUMRAMON VALENCIAAPPROVEDPM

 08/07/2019EXPIRATION NOTICE SELORNA MASONCOMPLETED9/23/2019 12:00:00 AM Contractor exp letter returned

 03/19/2019033-UNDERFLOOR ELECSHAIN NIVENAPPROVED3/19/2019 12:00:00 AM Conduit at slab location approved

 11/15/2019130-ALL FINALS**MICHAEL EMERYCORRECTION NOTICEEarly AM11/15/2019 5:07:49 PM NOT A FULL INSPECTION PULL FEEDER INTO BOX ISOLATE ROUNDED CONDUCTOR FROM EQUIPMENT CONDUCTOR NO PHASE TAPE ON #6 ONE RESTROOM NOT OPEN TO INSPECT PLUMBING NOT TOPPED OFF NO RECORDS OF SLAB OR UFER INSPECTION TIME CLOCK NOT PER TITLE 24 OPEN ALL J BOXES FOR INSPECTION NO PLANS OR JOB CARD ON SITE NEED ADA INSPECTION BUILDING LACKING POWER TO TEST GFCI INSPECTION STOPPED NEED CONTRATOR ON SITE FOR FUTURE INSPECTIONS

 11/26/2019130-ALL FINALS**MICHAEL EMERYNO ACCESS11/26/2019 2:33:00 PM Nobody on site. Couldn't find plans or job card, gated around the park,play structure and shade structure.

 12/03/2019130-ALL FINALS**RAMON VALENCIANO ACCESSPlease call before! 916-533-359112/3/2019 9:45:31 AM Contractor not on site.

 05/04/2020EXPIRATION NOTICE SELORNA MASONCOMPLETED

 05/18/2020EXTENTIONLORNA MASONAPPROVEDsee attachment

 10/26/2020EXPIRATION NOTICE SELORNA MASONCOMPLETED

 06/07/2021FINAL BUILDING**RAMON VALENCIAROLL OVER

 06/07/2021FINAL ACCESSIBILITYRAMON VALENCIAROLL OVER

 06/08/2021FINAL BUILDING**SHAIN NIVENROLL OVER

 06/08/2021FINAL ACCESSIBILITYSHAIN NIVENROLL OVER

 06/09/2021FINAL ACCESSIBILITYSTEVE MONCURROLL OVER

 06/09/2021FINAL BUILDING**RAMON VALENCIAROLL OVER

 06/10/2021FINAL ACCESSIBILITYRAMON VALENCIAROLL OVER

 06/10/2021FINAL BUILDING**RAMON VALENCIAROLL OVER

 06/11/2021FINAL BUILDING**RAMON VALENCIANOT READY

 12/04/2019130-ALL FINALS**STEVE MONCURCORRECTION NOTICE12/4/2019 11:33:30 AM Information only given to Tom No handle ties on breakers Both pedestal not labeled Load exceeds amps and over current protection Missing caps for conduit at both pedestal Remove main bonding jumper at stainless pedestal Underground conduit not accounted for needs pot holing Bath load center needs to be handle tried Single one does show main sizes for feeder and over current load is 58.38 installed is a 20 amp Top off plumbing No records of footing or underground electrical Remove electrical covers for inspection No plans on site for shade structure Advised we need electrician on site for inspection

 12/04/2019140-FINAL ACCESSIBILSTEVE MONCURCORRECTION NOTICE12/4/2019 11:33:26 AM Information only given to Tom No handle ties on breakers Both pedestal not labeled Load exceeds amps and over current protection Missing caps for conduit at both pedestal Remove main bonding jumper at stainless pedestal Underground conduit not accounted for needs pot holing Bath load center needs to be handle tried Single one does show main sizes for feeder and over current load is 58.38 installed is a 20 amp Top off plumbing No records of footing or underground electrical Remove covers for inspection

 06/11/2021FINAL ACCESSIBILITYSTEVE MONCURROLL OVER

 06/15/2021FINAL ACCESSIBILITYRAMON VALENCIACANCELLED

 09/23/2021FINAL ACCESSIBILITYCHRISTOPHER LANDRETHAPPROVED

 09/23/2021FINAL BUILDING**CHRISTOPHER LANDRETHAPPROVED