On the day of a scheduled inspection, customers can call the City of Tracy at 209-831-6400 any time after 8:00 a.m.  The City of Tracy will then give you the assigned inspector’s name and cell phone number.  Customers can then contact the inspector to get an estimated timeframe as to when the inspector will arrive for the inspection.

 
Permit No. 19-0949 Permit Type   ADDITION Site Address   41 W HIGHLAND AV
TRACY, CA 95376
Applied   04/22/2019 Applicant   LUIS CHAVEZ
Approved   12/05/2019 Owner   ONKAR BUILDERS
Issued   12/18/2019 Contractor   OWNER BUILDER
Parent Permit No.   Description   1,883 SQ FT ADDITION TO SFD AND REMODEL W/ GARAGE
  Notes   (4/22/2019 1:11 PM LWE) FRONT UNITS (4/24/2019 2:03 PM ANB) rcpt # 4207-0022 (5/15/2019 11:42 AM KM) (5/15/2019 11:32 AM KM) An existing one-family dwelling (with questionable second dwelling) to be remodeled/expanded/converted to two-family dwelling (7/12/2019 8:31 AM ANGB) ADDED INVESTIGATIVE FEES PER CODE ENFORCEMENT BA
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 03/30/2020FOOTINGS / PIERSBRAD FIELDSCANCELLED

 08/21/2020EXPIRATION NOTICE SELORNA MASONCOMPLETED

 09/16/2020EXTENTIONLORNA MASONAPPROVEDsee attachment

 09/24/2020PRE-CONSTRUCTION MEETINGTIM NAKASHIMANO ACCESS9/24/2020 3:07:53 PM Arrived 1:15 PM nobody on site lot is fenced off no access left door knocker 1:20 PM.

 09/29/2020PRE-CONSTRUCTION MEETIM NAKASHIMACOMPLETED9/29/2020 2:30:17 PM Met with "new" general contractor on site today. He advised that he just took over project and wanted to inquire as to remodel vs. demo and new build,as plans show as remodel leaving front and side exterior walls to remain,also sub floor joists do not match what is currently there. I advised him to have an on site meeting with the engineer to preform a walk through to address any concerns prior to construction,as we can only approve what has been approved through plan check.

 11/19/2020FOOTINGS / PIERSDEREK POEAPPROVED11/18/2020 2:38:08 PM Bill 209-480-2275 11/19/2020 10:22:27 AM Setbacks also approved. ADU only. No card on site. Signed plans. 11/19/2020 10:45:02 AM Setbacks also approved. ADU only. No card on site. Signed plans.

 01/04/2021UNDERGROUND PLUMBINGDEREK POECORRECTION NOTICE1/4/2021 12:49:50 PM Wrong permit number used. This lot has two permits. This particular permit is for the main structure in which the contractor is in negotiations with the city for "one wall" authorization. At the time of this inspection contractor indicated that he has a verbal OK from the city and would like to start using this permit. Informed him that I have not received confirmation therefore we will continue to use the other permit specifically for the ADU. Contractor wanted to speak directly about the main structure. Informed him that I'll conversations in regards to this permit number should be between him and BO.

 01/14/2021UNDER FLOOR INSULATIONDEREK POECORRECTION NOTICE1/14/2021 9:42:53 AM Inspection scheduled under the wrong permit again. Have spoken with the contractor to indicate that we are using the permit specific for the ADU until problems are resolved with main structure. No permit card on site have requested a permit card multiple times.

 02/23/2021FOOTINGS / PIERSBRAD FIELDSCORRECTION NOTICE2/23/2021 12:04:39 PM Need to do underground inspection before slab approval

 02/24/2021UNDERGROUND PLUMBINGBRAD FIELDSPARTIAL APPROVAL2/24/2021 8:48:40 AM bf changed Inspection Type from UNDER FLOOR PLUMBING to UNDERGROUND PLUMBING 2/24/2021 8:54:56 AM Underground sewer tie in to under foundation only approved. Still need new water line to be installed

 02/24/2021SETBACKSBRAD FIELDSAPPROVED

 02/24/2021FOOTINGS / PIERSBRAD FIELDSAPPROVED

 02/24/2021UFER GROUNDBRAD FIELDSAPPROVED

 03/16/2021UNDER FLOOR PLUMBINGBRAD FIELDSCORRECTION NOTICEeTRAKiT Inspection Request3/12/2021 11:06:05 AM 3/12/2021 11:06 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 3/16/2021 11:59:00 AM Mainline going to toilets in middle of house needs to have clean out extended through foundation

 03/17/2021UNDER FLOOR PLUMBINGBRAD FIELDSAPPROVEDeTRAKiT Inspection Request3/16/2021 2:14:59 PM 3/16/2021 2:14 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 03/17/2021UNDER FLOOR FRAMINGBRAD FIELDSNOT READYeTRAKiT Inspection Request3/16/2021 2:14:59 PM 3/16/2021 2:14 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 03/18/2021UNDER FLOOR FRAMINGBRAD FIELDSAPPROVEDeTRAKiT Inspection Request3/17/2021 10:51:24 AM 3/17/2021 10:51 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 03/29/2021UNDER FLOOR INSULATIONSTEVE MONCURAPPROVEDeTRAKiT Inspection Request3/25/2021 10:05:42 AM 3/25/2021 10:05 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com; bill@onkarbuilders.com 3/29/2021 9:26:22 AM R-19 3/29/2021 11:02:18 AM R-19

 03/30/2021FLOOR DIAPHRAGMSTEVE MONCURAPPROVEDeTRAKiT Inspection Request3/29/2021 9:52:20 AM 3/29/2021 9:52 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 04/07/2021FLOOR DIAPHRAGMSTEVE MONCURNO ACCESSeTRAKiT Inspection Request4/6/2021 12:42:33 PM 4/6/2021 12:42 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 4/7/2021 9:51:40 AM See attachment

 04/08/2021FLOOR DIAPHRAGMSTEVE MONCURCORRECTION NOTICEeTRAKiT Inspection Request4/7/2021 1:16:05 PM 4/7/2021 1:16 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 4/8/2021 11:40:21 AM 2 x 10 floor Joist are actually 2 x 9 get approval from engineer that the missing half inch will still suffice Approved plans call for 2 x 10 which should make them 9 inches in the 1/2 inches deep. Missing double two by tens where circled with pink highlighter. Joyce possibly going the wrong way second bedroom. A bit confusing. Spot checked floor joist spacing living room was 18 inches on center check throughout approved plans require 16 inches on center. Master bedroom floor Joist are going to wrong way this i has been discovered in several rooms before we can sign off the floor nailin we need to get this remedied. End

 04/14/2021FLOOR DIAPHRAGMSHAIN NIVENCORRECTION NOTICEeTRAKiT Inspection Request4/13/2021 11:08:28 AM 4/13/2021 11:08 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 4/14/2021 3:01:44 PM Plans call for flat 2x blocking at floor diaphragm edges. See previous corrections dated 4/8/21, for outstanding corrections required to be completed prior to floor diaphragm approval.

 04/15/2021FLOOR DIAPHRAGMSTEVE MONCURAPPROVED4/15/2021 8:30:42 AM Revisions not on site. EOR walked the changes Wednesday top nailing was appropriately nailed. Ok to stand second floor walls. Can confirm new beams and pressure blocking at next inspection (frame)

 04/16/2021FLOOR DIAPHRAGMSHAIN NIVENCANCELLED

 04/19/2021FLOOR DIAPHRAGMSTEVE MONCURCORRECTION NOTICE4/19/2021 11:27:22 AM Spoke to owner, advised final floor approval in review with city currently. When that is signed off we can then sign your permit. Note you are using PT lumber this will require galvanized nails. The nails you have are vinyl sinkers disapproved.

 05/18/2021ROUGH PLUMBINGSTEVE MONCURCANCELLEDeTRAKiT Inspection Request5/17/2021 1:25:15 PM 5/17/2021 1:25 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 5/18/2021 7:55:09 AM scheduled for wrong permit

 06/02/2021ROOF NAIL/DIAPHRAGMWLADYSLAW GROBELNYAPPROVEDeTRAKiT Inspection Request6/1/2021 9:12:16 AM 6/1/2021 9:12 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 6/2/2021 4:04:33 PM wgb changed Inspection Type from ROOF NAIL/DIAPHRAGM to UNDERGROUND PLUMBING

 06/02/2021EXTERIOR SHEARWLADYSLAW GROBELNYCORRECTION NOTICEeTRAKiT Inspection Request6/1/2021 9:12:16 AM 6/1/2021 9:12 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 6/2/2021 4:33:57 PM Shear wall nailing not according to the schedule of shear wall

 06/03/2021EXTERIOR SHEARWLADYSLAW GROBELNYNOT READYeTRAKiT Inspection Request6/2/2021 3:23:01 PM 6/2/2021 3:22 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 06/07/2021EXTERIOR SHEARWLADYSLAW GROBELNYAPPROVEDeTRAKiT Inspection Request6/3/2021 6:52:59 PM 6/3/2021 6:52 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 06/07/2021INTERIOR SHEARWLADYSLAW GROBELNYAPPROVED

 06/08/2021ROUGH FRAMEWLADYSLAW GROBELNYAPPROVED

 07/19/2021ROUGH PLUMBINGSTEVE MONCURCANCELLEDeTRAKiT Inspection Request7/16/2021 2:25:50 PM 7/16/2021 2:25 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 07/19/2021ROUGH MECHANICALSTEVE MONCURCANCELLEDeTRAKiT Inspection Request7/16/2021 2:25:51 PM 7/16/2021 2:25 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 07/19/2021ROUGH ELECTRICALSTEVE MONCURCANCELLEDeTRAKiT Inspection Request7/16/2021 2:25:51 PM 7/16/2021 2:25 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 07/19/2021FIRE SPRINKLER ROUGHSTEVE MONCURCANCELLEDeTRAKiT Inspection Request7/16/2021 2:25:51 PM 7/16/2021 2:25 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 07/21/2021ROUGH MECHANICALSTEVE MONCURCORRECTION NOTICE

 07/21/2021ROUGH ELECTRICALSTEVE MONCURNOT READY7/21/2021 1:33:28 PM Feeders still being run

 07/21/2021FINAL RES FIRE SPRKINLERSTEVE MONCURCORRECTION NOTICE7/21/2021 1:33:30 PM Inspector requested larger plans 8.5x11 sheet too small to read. Completed hydro test. No leaks heads clean. Contact on-site said that was all they needed. Was told ADU sprinklers done. Recall for tomorrow leave larger set inside for inspector.

 07/27/2021ROUGH ELECTRICALSTEVE MONCURCORRECTION NOTICEeTRAKiT Inspection Request7/23/2021 6:37:26 PM 7/23/2021 6:37 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/28/2021 7:01:30 AM 41 w highland. Hold downs are loose bedroom 3. Provide 6 ladder , was told left at other jobsite. Fan box might be too small cu. inch. Seal all register openings during construction. Missing fan switch bed bed2 hold downs loose, missing 3 way switch, ceiling fan box might be too small cu. inch. Check all hold downs. Move windows at interior living room for rough electrical inspection. Maybe several misinstalled hold downs will check Simpson catalog. Missing plug int living room. Missing plug m bedroom. Missing wall switch m. Bedroom. Missing plug at 2 ft. Wall m. Bed. Kitchen plumbing not topped off. Over notched plumbing ext wall. Separate or derate 12 gauge bundling. Bvent requires 1 inch clearance from combustibles. Need ladder. Underfloor clearance to dirt? 16? Missing stringer fire block near mid landing. Block two sides of bathroom exhausts. Per shall be 12 inches away from down lights. Need 8 ft. Ladder for attic condensate looks flat. Block two sides of exhaust fan. Sub panels in laundry not ready , plans do not show sink in play rooms upstairs, separate foil back from gas line. Kids play room second floor. Charge domestic water lines. Romex not supported kids seco

 07/21/2021ROUGH PLUMBINGSTEVE MONCURCORRECTION NOTICE7/21/2021 1:33:23 PM Plumbing not under test Contractor said only sprinkler test needed 7/28/2021 7:57:08 AM 41 w highland. Hold downs are loose bedroom 3. Provide 6 ladder , was told left at other jobsite. Fan box might be too small cu. inch. Seal all register openings during construction. Missing fan switch bed bed2 hold downs loose, missing 3 way switch, ceiling fan box might be too small cu. inch. Check all hold downs. Move windows at interior living room for rough electrical inspection. Maybe several misinstalled hold downs will check Simpson catalog. Missing plug int living room. Missing plug m bedroom. Missing wall switch m. Bedroom. Missing plug at 2 ft. Wall m. Bed. Kitchen plumbing not topped off. Over notched plumbing ext wall. Separate or derate 12 gauge bundling. Bvent requires 1 inch clearance from combustibles. Need ladder. Underfloor clearance to dirt? 16? Missing stringer fire block near mid landing. Block two sides of bathroom exhausts. Per shall be 12 inches away from down lights. Need 8 ft. Ladder for attic condensate looks flat. Block two sides of exhaust fan. Sub panels in laundry not ready , plans do not show sink in play rooms upstairs, separate foil back from gas line. Kids play room second floor. Charge domestic water lines. Romex not supported kids second level play room going to fan box. Missing nail plates. Revise plans for added sinks. Outside pancakes boxes too small for cubic inches of wire. Missing edge blocking at calif. romex not supported over second bathroom check all ceilings. Missing framing back side of bath tubs. Sprinkler too close to underside of roof sheathing NAILS Replace exterior stud at kitchen.

 07/28/2021FIRE SPRINKLER ROUGHSTEVE MONCURCORRECTION NOTICEeTRAKiT Inspection Request7/23/2021 6:37:26 PM 7/23/2021 6:37 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/28/2021 7:57:17 AM 41 w highland. Hold downs are loose bedroom 3. Provide 6 ladder , was told left at other jobsite. Fan box might be too small cu. inch. Seal all register openings during construction. Missing fan switch bed bed2 hold downs loose, missing 3 way switch, ceiling fan box might be too small cu. inch. Check all hold downs. Move windows at interior living room for rough electrical inspection. Maybe several misinstalled hold downs will check Simpson catalog. Missing plug int living room. Missing plug m bedroom. Missing wall switch m. Bedroom. Missing plug at 2 ft. Wall m. Bed. Kitchen plumbing not topped off. Over notched plumbing ext wall. Separate or derate 12 gauge bundling. Bvent requires 1 inch clearance from combustibles. Need ladder. Underfloor clearance to dirt? 16? Missing stringer fire block near mid landing. Block two sides of bathroom exhausts. Per shall be 12 inches away from down lights. Need 8 ft. Ladder for attic condensate looks flat. Block two sides of exhaust fan. Sub panels in laundry not ready , plans do not show sink in play rooms upstairs, separate foil back from gas line. Kids play room second floor. Charge domestic water lines. Romex not supported kids second level play room going to fan box. Missing nail plates. Revise plans for added sinks. Outside pancakes boxes too small for cubic inches of wire. Missing edge blocking at calif. romex not supported over second bathroom check all ceilings. Missing framing back side of bath tubs. Sprinkler too close to underside of roof sheathing NAILS Replace exterior stud at kitchen.

 07/28/2021ROUGH MECHANICALSTEVE MONCURCORRECTION NOTICEeTRAKiT Inspection Request7/23/2021 6:37:26 PM 7/23/2021 6:37 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/28/2021 7:01:27 AM 41 w highland. Hold downs are loose bedroom 3. Provide 6 ladder , was told left at other jobsite. Fan box might be too small cu. inch. Seal all register openings during construction. Missing fan switch bed bed2 hold downs loose, missing 3 way switch, ceiling fan box might be too small cu. inch. Check all hold downs. Move windows at interior living room for rough electrical inspection. Maybe several misinstalled hold downs will check Simpson catalog. Missing plug int living room. Missing plug m bedroom. Missing wall switch m. Bedroom. Missing plug at 2 ft. Wall m. Bed. Kitchen plumbing not topped off. Over notched plumbing ext wall. Separate or derate 12 gauge bundling. Bvent requires 1 inch clearance from combustibles. Need ladder. Underfloor clearance to dirt? 16? Missing stringer fire block near mid landing. Block two sides of bathroom exhausts. Per shall be 12 inches away from down lights. Need 8 ft. Ladder for attic condensate looks flat. Block two sides of exhaust fan. Sub panels in laundry not ready , plans do not show sink in play rooms upstairs, separate foil back from gas line. Kids play room second floor. Charge domestic water lines. Romex not supported kids seco 7/28/2021 7:57:28 AM 41 w highland. Hold downs are loose bedroom 3. Provide 6 ladder , was told left at other jobsite. Fan box might be too small cu. inch. Seal all register openings during construction. Missing fan switch bed bed2 hold downs loose, missing 3 way switch, ceiling fan box might be too small cu. inch. Check all hold downs. Move windows at interior living room for rough electrical inspection. Maybe several misinstalled hold downs will check Simpson catalog. Missing plug int living room. Missing plug m bedroom. Missing wall switch m. Bedroom. Missing plug at 2 ft. Wall m. Bed. Kitchen plumbing not topped off. Over notched plumbing ext wall. Separate or derate 12 gauge bundling. Bvent requires 1 inch clearance from combustibles. Need ladder. Underfloor clearance to dirt? 16? Missing stringer fire block near mid landing. Block two sides of bathroom exhausts. Per shall be 12 inches away from down lights. Need 8 ft. Ladder for attic condensate looks flat. Block two sides of exhaust fan. Sub panels in laundry not ready , plans do not show sink in play rooms upstairs, separate foil back from gas line. Kids play room second floor. Charge domestic water lines. Romex not supported kids second level play room going to fan box. Missing nail plates. Revise plans for added sinks. Outside pancakes boxes too small for cubic inches of wire. Missing edge blocking at calif. romex not supported over second bathroom check all ceilings. Missing framing back side of bath tubs. Sprinkler too close to underside of roof sheathing NAILS Replace exterior stud at kitchen.

 07/28/2021ROUGH PLUMBINGSTEVE MONCURCORRECTION NOTICEeTRAKiT Inspection Request7/23/2021 6:37:26 PM 7/23/2021 6:37 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/28/2021 7:01:25 AM 41 w highland. Hold downs are loose bedroom 3. Provide 6 ladder , was told left at other jobsite. Fan box might be too small cu. inch. Seal all register openings during construction. Missing fan switch bed bed2 hold downs loose, missing 3 way switch, ceiling fan box might be too small cu. inch. Check all hold downs. Move windows at interior living room for rough electrical inspection. Maybe several misinstalled hold downs will check Simpson catalog. Missing plug int living room. Missing plug m bedroom. Missing wall switch m. Bedroom. Missing plug at 2 ft. Wall m. Bed. Kitchen plumbing not topped off. Over notched plumbing ext wall. Separate or derate 12 gauge bundling. Bvent requires 1 inch clearance from combustibles. Need ladder. Underfloor clearance to dirt? 16? Missing stringer fire block near mid landing. Block two sides of bathroom exhausts. Per shall be 12 inches away from down lights. Need 8 ft. Ladder for attic condensate looks flat. Block two sides of exhaust fan. Sub panels in laundry not ready , plans do not show sink in play rooms upstairs, separate foil back from gas line. Kids play room second floor. Charge domestic water lines. Romex not supported kids seco 7/28/2021 7:57:34 AM 41 w highland. Hold downs are loose bedroom 3. Provide 6 ladder , was told left at other jobsite. Fan box might be too small cu. inch. Seal all register openings during construction. Missing fan switch bed bed2 hold downs loose, missing 3 way switch, ceiling fan box might be too small cu. inch. Check all hold downs. Move windows at interior living room for rough electrical inspection. Maybe several misinstalled hold downs will check Simpson catalog. Missing plug int living room. Missing plug m bedroom. Missing wall switch m. Bedroom. Missing plug at 2 ft. Wall m. Bed. Kitchen plumbing not topped off. Over notched plumbing ext wall. Separate or derate 12 gauge bundling. Bvent requires 1 inch clearance from combustibles. Need ladder. Underfloor clearance to dirt? 16? Missing stringer fire block near mid landing. Block two sides of bathroom exhausts. Per shall be 12 inches away from down lights. Need 8 ft. Ladder for attic condensate looks flat. Block two sides of exhaust fan. Sub panels in laundry not ready , plans do not show sink in play rooms upstairs, separate foil back from gas line. Kids play room second floor. Charge domestic water lines. Romex not supported kids second level play room going to fan box. Missing nail plates. Revise plans for added sinks. Outside pancakes boxes too small for cubic inches of wire. Missing edge blocking at calif. romex not supported over second bathroom check all ceilings. Missing framing back side of bath tubs. Sprinkler too close to underside of roof sheathing NAILS Replace exterior stud at kitchen.

 08/06/2021ROUGH MECHANICALSTEVE MONCURROLL OVEReTRAKiT Inspection Request8/5/2021 1:50:08 PM 8/5/2021 1:50 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 8/6/2021 10:50:03 AM Inspector had to leave early today ran out of time. Please make first stop on Monday Call 209.831.6400

 08/06/2021ROUGH ELECTRICALSTEVE MONCURCORRECTION NOTICEeTRAKiT Inspection Request8/5/2021 1:50:06 PM 8/5/2021 1:50 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 8/6/2021 10:50:07 AM Change ceiling fan boxes bedrooms 6.0 cu in. Too small. Outside ones good Support romex kids play room every 5 ft. Check all room.

 08/09/2021ROUGH MECHANICALRYAN FEATHERSTONEAPPROVEDeTRAKiT Inspection Request8/9/2021 3:18:57 PM Corrections completed from 8/5/21 And all trades frame re-inspected contractor to revise plans showing sink in playroom

 08/09/2021FIRE SPRINKLER ROUGHRYAN FEATHERSTONEAPPROVEDeTRAKiT Inspection Request8/6/2021 11:02:02 AM 8/6/2021 11:02 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 08/09/2021ROUGH PLUMBINGRYAN FEATHERSTONEAPPROVEDeTRAKiT Inspection Request8/6/2021 11:01:29 AM 8/6/2021 11:01 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 08/09/2021ROUGH MECHANICALRYAN FEATHERSTONEAPPROVEDeTRAKiT Inspection Request8/6/2021 11:01:29 AM 8/6/2021 11:01 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 08/09/2021ROUGH ELECTRICALRYAN FEATHERSTONEAPPROVEDeTRAKiT Inspection Request8/6/2021 11:01:29 AM 8/6/2021 11:01 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 8/9/2021 3:19:51 PM Corrections completed from 8/5/21 And all trades frame re-inspected contractor to revise plans showing sink in playroom Two receptacle outlets added at downstairs bedroom window location Ceiling fan box changed upstairs bedrooms approved

 08/16/2021WALL INSULATIONJIM DECKERNO ACCESS

 08/17/2021WALL INSULATIONJIM DECKERAPPROVEDeTRAKiT Inspection Request8/16/2021 3:08:58 PM 8/16/2021 3:08 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 08/17/2021LATHJIM DECKERAPPROVED

 08/30/2021DRYWALL NAIL - 1ST LAYERMARK PRZYBUSCORRECTION NOTICEeTRAKiT Inspection Request8/27/2021 7:45:27 AM 8/27/2021 7:45 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 8/30/2021 9:58:49 AM 1. Screws at interior shear walls need to be 1 5/8" or longer. 2. Missing backer board in bathrooms. Need to recall inspection when install is complete. 3. Shower pan in bathroom not ready to install walls. No pan, no hot mop,

 09/02/2021DRYWALL NAIL - 1ST LAYERMARK PRZYBUSAPPROVEDeTRAKiT Inspection Request9/1/2021 10:09:10 AM 9/1/2021 10:09 AM Nav Sandhu shower pan and wet wall will be called in as a separate inspection. Thank you Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 10/05/2021WET WALLMARK PRZYBUSCORRECTION NOTICEeTRAKiT Inspection Request10/4/2021 7:51:39 AM 10/4/2021 7:51 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 10/5/2021 9:22:06 AM 1. Shower pans are not hot mopped yet. 2. Need to change out drywall screws at purple board at all bathrooms to corrosion resistant screws.

 10/05/2021ELECTRIC SERVICEMARK PRZYBUSCORRECTION NOTICEeTRAKiT Inspection Request10/4/2021 7:51:39 AM 10/4/2021 7:51 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 10/5/2021 1:55:12 PM 1. Main panel not opened and ready for inspection. 2. Ground wire not hooked up. 3. Wires feeding sub panel not hooked up. 4. You need at least one circuit connected in order to get a release and have PG&E energize the panel. Fix corrections and recall inspection

 10/21/2021ELECTRIC SERVICEJIM DECKERAPPROVEDSee notes.10/19/2021 2:59:38 PM 10/19/2021 2:59 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 10/21/2021 3:44:35 PM Elect service OK for P.G. & E. release. Only one meter will be released this day; 41 West Highland Ave (main house).

 10/21/2021WET WALLJIM DECKERAPPROVED

 12/21/2021FOOTINGS / PIERSRYAN FEATHERSTONEAPPROVED12/21/2021 9:34:44 AM Footing and slab for garage

 12/21/2021GAS TESTRYAN FEATHERSTONEAPPROVED

 02/10/2022FINAL PLUMBING**MARK PRZYBUSCORRECTION NOTICEeTRAKiT Inspection Request2/9/2022 5:53:39 PM 2/9/2022 5:53 PM Nav Sandhu Sewer connection Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 2/10/2022 7:07:28 PM This was a pre-plumbing inspection for determination of city plan requirements of sewer lines of single family homes. Contractor instructed that further research was needed to give guide lines. Contractor to reschedule inspection for next week to discuss details of research.

 02/17/2022ROUGH FRAMEWLADYSLAW GROBELNYCORRECTION NOTICEeTRAKiT Inspection Request2/16/2022 2:47:31 PM 2/16/2022 2:47 PM Nav Sandhu Garage Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 2/17/2022 2:21:31 PM All notes below apply to the garage only 1. Install anchor bolts 4"-12" from end of the mud sill 2. Ok to install lath on exterior walls

 02/17/2022ROUGH ELECTRICALWLADYSLAW GROBELNYCORRECTION NOTICEeTRAKiT Inspection Request2/16/2022 2:47:31 PM 2/16/2022 2:47 PM Nav Sandhu Garage Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 2/17/2022 2:21:35 PM All notes below apply to the garage only 1. Replace metal LB fitting under the subpanel, all electrical fittings shall be accessible 2. The conduit is installed from the subpanel to exterior wall only. No wires installed in the conduit 3. Install the ground rod for the garage

 02/17/2022ROOF NAIL/DIAPHRAGMWLADYSLAW GROBELNYAPPROVEDeTRAKiT Inspection Request2/16/2022 2:47:31 PM 2/16/2022 2:47 PM Nav Sandhu Garage Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 2/17/2022 2:21:39 PM Ok to install the roofing

 03/02/2022ROUGH FRAMEWLADYSLAW GROBELNYPARTIAL APPROVALeTRAKiT Inspection Request2/28/2022 4:48:43 PM 2/28/2022 4:48 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 3/2/2022 12:59:49 PM Rough frame approved on the garage only 3/2/2022 1:06:20 PM Rough frame approved on the garage only 3/2/2022 1:08:44 PM Rough frame approved on the garage only 3/2/2022 1:41:59 PM Rough frame approved on the garage only 3/2/2022 2:01:51 PM Rough frame approved on the garage only

 03/02/2022ROUGH ELECTRICALWLADYSLAW GROBELNYPARTIAL APPROVALeTRAKiT Inspection Request2/28/2022 4:48:43 PM 2/28/2022 4:48 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 3/2/2022 12:59:55 PM 1. Wiring inside the garage approved 2. The conduit is installed from the subpanel to exterior wall only. No wires installed in the conduit 3/2/2022 1:06:23 PM 1. Wiring inside the garage approved 2. The conduit is installed from the subpanel to exterior wall only. No wires installed in the conduit 3/2/2022 1:08:46 PM 1. Wiring inside the garage approved 2. The conduit is installed from the subpanel to exterior wall only. No wires installed in the conduit 3/2/2022 1:42:02 PM 1. Wiring inside the garage approved 2. The conduit is installed from the subpanel to exterior wall only. No wires installed in the conduit 3/2/2022 2:01:53 PM 1. Wiring inside the garage approved 2. The conduit is installed from the subpanel to exterior wall only. No wires installed in the conduit

 04/11/2022DRYWALL NAIL - 1ST LAYERWLADYSLAW GROBELNYAPPROVEDGARAGE ONLY4/8/2022 4:13:20 PM 4/8/2022 4:13 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 4/11/2022 12:21:11 PM Drywall inspection for the garage only 4/11/2022 2:10:05 PM Drywall inspection for the garage only 4/11/2022 2:56:28 PM Drywall inspection for the garage only

 04/11/2022UNDERGROUND ELECTRICALWLADYSLAW GROBELNYAPPROVED4/11/2022 2:57:30 PM Underground conduit for the garage sub panel

 04/12/2022UNDERGROUND ELECTRICALWLADYSLAW GROBELNYALREADY DONEeTRAKiT Inspection Request4/11/2022 10:26:57 AM 4/11/2022 10:26 AM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 4/12/2022 10:29:41 AM Already done 04/11/22

 04/27/2022UNDERGROUND PLUMBINGWLADYSLAW GROBELNYCORRECTION NOTICEeTRAKiT Inspection Request4/26/2022 12:12:34 PM 4/26/2022 12:12 PM Nav Sandhu Water / sewer Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 4/27/2022 10:00:16 PM DWV not on test No plans on site to verify the size of the water service pipe

 04/29/2022UNDERGROUND PLUMBINGWLADYSLAW GROBELNYPARTIAL APPROVALeTRAKiT Inspection Request4/28/2022 3:46:25 PM 4/28/2022 3:46 PM Nav Sandhu Sewer Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 4/29/2022 11:17:30 AM DWV Underground sewer approved. Water service not ready

 05/23/2022UNDERGROUND PLUMBINGROBERT HALLPARTIAL APPROVALeTRAKiT Inspection Request5/20/2022 2:07:14 PM 5/20/2022 2:07 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 5/23/2022 10:02:33 AM AP water line from meter to ADU

 05/27/2022GAS SERVICEJAMES ALLISONAPPROVEDeTRAKiT Inspection Request5/26/2022 2:17:13 PM 5/26/2022 2:17 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 07/11/2022FINAL RES FIRE SPRKINLERROBERT HALLCORRECTION NOTICEeTRAKiT Inspection Request7/8/2022 2:16:56 PM 7/8/2022 2:16 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/11/2022 11:20:43 AM 1. Fire bell did not sound upon draining down line 2. Terminate discharge line in approved manner

 07/18/2022FINAL RES FIRE SPRKINLERROBERT HALLCORRECTION NOTICEeTRAKiT Inspection Request7/15/2022 5:27:05 PM 7/15/2022 5:26 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/18/2022 1:17:29 PM See final building corrections

 07/18/2022FINAL PLUMBING**ROBERT HALLCORRECTION NOTICEeTRAKiT Inspection Request7/15/2022 5:27:04 PM 7/15/2022 5:26 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/18/2022 1:17:32 PM See final building corrections

 07/18/2022FINAL MECHANICAL**ROBERT HALLCORRECTION NOTICEeTRAKiT Inspection Request7/15/2022 5:27:04 PM 7/15/2022 5:26 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/18/2022 1:17:36 PM See final building corrections

 07/18/2022FINAL HVAC**ROBERT HALLCORRECTION NOTICEeTRAKiT Inspection Request7/15/2022 5:27:04 PM 7/15/2022 5:26 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/18/2022 1:17:39 PM See final building corrections

 07/18/2022FINAL ELECTRICAL**ROBERT HALLCORRECTION NOTICEeTRAKiT Inspection Request7/15/2022 5:27:04 PM 7/15/2022 5:26 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/18/2022 1:17:42 PM See final building corrections

 07/18/2022FINAL BUILDING**ROBERT HALLCORRECTION NOTICEeTRAKiT Inspection Request7/15/2022 5:27:04 PM 7/15/2022 5:26 PM Nav Sandhu Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/18/2022 1:17:45 PM 1. Upper guardrail needs to be 42" min from deck 2. Duct for kitchen hood needs to be approved materials 3. Water heater closet needs combustion air 4. Terminate w/h T&P to exterior 5. Need anti-siphon at hose bibs 6. Complete stucco at patch around plumbing clean outs 7. Rear entry steps (exterior) have risers higher than max allowed 8. Close opening in stucco below main service panel 9. Terminate PVC drain lines with elbows including fire sprinkler drain 10. Provide access to attic for inspection 11. Provide screening at subfloor access door on exterior

 07/18/2022LATHROBERT HALLAPPROVED7/18/2022 1:17:47 PM AP for lath at patch around plumbing DWV penetrations - East side

 07/25/2022FINAL BUILDING**ROBERT HALLAPPROVEDeTRAKiT Inspection Request7/21/2022 7:06:50 PM 7/21/2022 7:06 PM Nav Sandhu Requesting Robert Hall who was out previously for final building Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com 7/21/2022 7:08:07 PM 7/21/2022 7:08 PM Nav Sandhu Requesting Robert Hall who was out previously for final building Contact Name: Nav Sandhu Site Address: 41 W HIGHLAND AV Phone: 2098727812 e-Mail: nav@rbwrestores.com

 07/25/2022FINAL ELECTRICAL**ROBERT HALLAPPROVED

 07/25/2022FINAL PLUMBING**ROBERT HALLAPPROVED

 07/25/2022FINAL RES FIRE SPRKINLERROBERT HALLAPPROVED

 07/25/2022FINAL MECHANICAL**ROBERT HALLAPPROVED