On the day of a scheduled inspection, customers can call the City of Tracy at 209-831-6400 any time after 8:00 a.m.  The City of Tracy will then give you the assigned inspector’s name and cell phone number.  Customers can then contact the inspector to get an estimated timeframe as to when the inspector will arrive for the inspection.

 
Permit No. 19-2418 Permit Type   PHOTOVOLTAIC Site Address   2039 LARA CT
TRACY, CA 95376
Applied   08/27/2019 Applicant   SINAI HERNANDEZ
Approved   10/08/2019 Owner   ESTRELLA, JOEL & NORMA R
Issued   10/10/2019 Contractor   BRIGHT PLANET SOLAR
Parent Permit No.   Description   11.1KW ROOF MOUNT SOLAR
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

134-FINAL ELEC**CANCELLEDVOIDED (CS 11/26/2019)11/26/2019 12:19:05 PM Inspection voided by CS. Most recent remarks follow: WILL RESCHEDULE

 11/26/2019092-ELECT SERVICEJAMES ALLISONNO ACCESS11/26/2019 1:33:09 PM Ring doorbell twice and not left correction notice to have contractor on site to facilitate inspection and open all electrical equipment for inspection.

 12/11/2019092-ELECT SERVICEBRAD FIELDSAPPROVED

 12/16/2019134-FINAL ELEC**JAMES ALLISONCORRECTION NOTICE12/16/2019 11:32:39 AM Provide permanent plaque showing all equipment and arrays. Multiple tile replacement flashings are bent and/or warped throughout both east and west arrays. Repair or replace as needed. Replacement flashings shall be installed per the manufacturers installation instructions and sealed if required. On west array seat all tiles properly per the listing of the concrete tile manufacturer. On east array support conduit at junction box. Conduit can not be solely supported by the box and lb. Provide rapid shutdown test. All other ok. Co collected.

 12/31/2019132-FINAL BLDG**RAMON VALENCIANOT READYeTRAKiT Inspection Request12/27/2019 4:00:03 PM 12/27/2019 3:59 PM BRIGHT PLANET SOLAR Point of Contact: Moises Navarrete (925) 339-6292 Contact Name: BRIGHT PLANET SOLAR Site Address: 2039 LARA CT Phone: 9253495289 e-Mail: serenal@brightplanetsolar.com 12/31/2019 10:23:55 AM See previous correction from James Allison.

 01/09/2020132-FINAL BLDG**JAMES ALLISONCORRECTION NOTICEeTRAKiT Inspection Request1/8/2020 9:46:25 AM 1/8/2020 9:46 AM BRIGHT PLANET SOLAR Contact Name: Mo Navarrete Site Address: 2039 LARA CT Phone: 9253396292 e-Mail: serenal@brightplanetsolar.com 1/9/2020 4:10:20 PM Still pending: Multiple tile replacement flashings are bent and/or warped throughout both east and west arrays. Repair or replace as needed. Replacement flashings shall be installed per the manufacturers installation instructions and sealed if required. See attached photos All other ok.

 01/23/2020132-FINAL BLDG**JAMES ALLISONAPPROVEDeTRAKiT Inspection Request1/16/2020 12:35:58 PM 1/16/2020 12:35 PM BRIGHT PLANET SOLAR Contact Name: Jeremy Hernandez Site Address: 2039 LARA CT Phone: 9253037383 e-Mail: serenal@brightplanetsolar.com