On the day of a scheduled inspection, customers can call the City of Tracy at 209-831-6400 any time after 8:00 a.m.  The City of Tracy will then give you the assigned inspector’s name and cell phone number.  Customers can then contact the inspector to get an estimated timeframe as to when the inspector will arrive for the inspection.

 
Permit No. RES20-0849 Permit Type   REMODEL Site Address   389 W 23RD ST
TRACY, CA 95376
Applied   06/30/2020 Applicant   MELO CONSTRUCTION INC
Approved   09/29/2020 Owner   WOOD, ANDREW F & JENNY
Issued   10/01/2020 Contractor   MELO CONSTRUCTION INC
Parent Permit No.   Description   INTERIOR REMODEL OF MASTER BATH, FAMILY ROOM & KITCHEN
  Notes  
 
  Date of Inspection Inspection Type Inspector Result Remarks Notes

 10/28/2020ROUGH PLUMBINGDEREK POEPARTIAL APPROVALeTRAKiT Inspection Request10/27/2020 6:31:36 PM 10/27/2020 6:31 PM MELO CONSTRUCTION INC All rough. Rough plumbing, rough framing, rough electrical, rough mechnical Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net 10/28/2020 3:19:11 PM New kitchen and family room area only

 10/28/2020ROUGH FRAMEDEREK POEPARTIAL APPROVAL10/28/2020 3:19:21 PM New kitchen and family room area only

 10/28/2020ROUGH MECHANICALDEREK POEPARTIAL APPROVAL10/28/2020 3:19:24 PM New kitchen and family room area only

 10/28/2020ROUGH ELECTRICALDEREK POEPARTIAL APPROVAL10/28/2020 3:19:28 PM New kitchen and family room area only

 10/28/2020ROUGH MECHANICALDEREK POEPARTIAL APPROVALPARTIAL APPROVAL10/28/2020 3:20:54 PM New kitchen and family room area only

 11/03/2020CEILING INSULATIONDEREK POEAPPROVEDeTRAKiT Inspection Request11/2/2020 11:26:05 AM 11/2/2020 11:26 AM MELO CONSTRUCTION INC Insulation inspection Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net

 11/03/2020WALL INSULATIONDEREK POEAPPROVED

 11/09/2020DRYWALL NAIL - 1ST LAYERDEREK POECORRECTION NOTICEeTRAKiT Inspection Request11/6/2020 12:54:48 PM 11/6/2020 12:54 PM MELO CONSTRUCTION INC Sheet rock & nail Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net 11/9/2020 11:48:53 AM 1. Extend 5/8 drywall on garage side up to bottom of roof.

 01/11/2021ROUGH ELECTRICALDEREK POEPARTIAL APPROVALeTRAKiT Inspection Request1/8/2021 11:18:40 AM 1/8/2021 11:18 AM MELO CONSTRUCTION INC Inspection is for all rought Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net 1/12/2021 7:23:58 AM Framing, electrical, and mechanical for new bedroom approved.

 01/12/2021WALL INSULATIONDEREK POEAPPROVEDeTRAKiT Inspection Request1/11/2021 4:01:20 PM 1/11/2021 4:01 PM MELO CONSTRUCTION INC Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net 1/12/2021 9:39:29 AM Wall insulation for bedroom approved

 01/14/2021DRYWALL NAIL - 1ST LAYERDEREK POEAPPROVEDeTRAKiT Inspection Request1/13/2021 12:08:50 PM 1/13/2021 12:08 PM MELO CONSTRUCTION INC Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net

 03/31/2021ROUGH PLUMBINGJAMES ALLISONCORRECTION NOTICEeTRAKiT Inspection Request3/26/2021 1:57:46 PM 3/26/2021 1:57 PM MELO CONSTRUCTION INC Inspection for ALL rough in master bathroom Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net 3/31/2021 3:42:48 PM At master bedroom and bathroom all roughs are complete. Ok to insulate. At underfloor plumbing a drain from the shower, sink, and laundry collect into a 2" drain line and exit the front of the house next to the 4" main drain and is capped. The contractor explained he talked to the city of Tracy and they would allow them to install a alternative nonpotable reclaimed water system to catch grey water from these drains. Per the records no such confirmation or review of this system has been conducted. Connect drains to main drain and test, or provide a design from a registered designed professional who demonstrates competency to design the alternate water source system per section 1501.2 of the CPC. If alternate system is to be used, change the scope of work to include this plumbing modification. Also, provide a plan showing the design and specs for all equipment to be used. See chapter 15 of the California plumbing code for all requirements, testing, and inspections needed for this system. See section 1503.1.1 for clothes washer systems.

 04/01/2021WALL INSULATIONJAMES ALLISONAPPROVEDeTRAKiT Inspection Request3/31/2021 11:39:37 AM 3/31/2021 11:39 AM MELO CONSTRUCTION INC Wall and ceiling Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net

 04/02/2021DRYWALL NAIL - 1ST LAYERJAMES ALLISONAPPROVEDeTRAKiT Inspection Request4/2/2021 12:29:10 PM 4/2/2021 12:29 PM MELO CONSTRUCTION INC Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net

 04/29/2021SHOWER PANRAMON VALENCIAAPPROVEDeTRAKiT Inspection Request4/28/2021 7:30:08 PM 4/28/2021 7:30 PM MELO CONSTRUCTION INC Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net

 06/16/2021FINAL BUILDING**WLADYSLAW GROBELNYCORRECTION NOTICEeTRAKiT Inspection Request6/15/2021 1:26:38 PM 6/15/2021 1:26 PM MELO CONSTRUCTION INC Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net 6/17/2021 11:07:22 AM 1. Dishwasher gfci not operating / wrong location 2. Verify ceiling fan boxes 3. Seal all plumbing penetrations between the garage and dwelling 4. Shower door not installed

 06/23/2021FINAL BUILDING**JAMES ALLISONAPPROVEDeTRAKiT Inspection Request6/22/2021 4:34:29 PM 6/22/2021 4:34 PM MELO CONSTRUCTION INC Contact Name: MELO CONSTRUCTION INC Site Address: 389 W 23RD ST Phone: 2098357314 e-Mail: melo.construction@sbcglobal.net 6/23/2021 8:46:54 AM All previous corrections complete. As an advisory, I told homeowner and contractor that existing door between the garage and living room shall be self-closing and self-latching and have a rating marked on the side. Co collected

 06/23/2021FINAL PLUMBING**JAMES ALLISONAPPROVED

 06/23/2021FINAL ELECTRICAL**JAMES ALLISONAPPROVED

 06/23/2021FINAL MECHANICAL**JAMES ALLISONAPPROVED