10/28/2020 | ROUGH PLUMBING | DEREK POE | PARTIAL APPROVAL | eTRAKiT Inspection Request | 10/27/2020 6:31:36 PM
10/27/2020 6:31 PM MELO CONSTRUCTION INC
All rough. Rough plumbing, rough framing, rough electrical, rough mechnical
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
10/28/2020 3:19:11 PM
New kitchen and family room area only
|
|
10/28/2020 | ROUGH FRAME | DEREK POE | PARTIAL APPROVAL | | 10/28/2020 3:19:21 PM
New kitchen and family room area only
|
|
10/28/2020 | ROUGH MECHANICAL | DEREK POE | PARTIAL APPROVAL | | 10/28/2020 3:19:24 PM
New kitchen and family room area only
|
|
10/28/2020 | ROUGH ELECTRICAL | DEREK POE | PARTIAL APPROVAL | | 10/28/2020 3:19:28 PM
New kitchen and family room area only
|
|
10/28/2020 | ROUGH MECHANICAL | DEREK POE | PARTIAL APPROVAL | PARTIAL APPROVAL | 10/28/2020 3:20:54 PM
New kitchen and family room area only
|
|
11/03/2020 | CEILING INSULATION | DEREK POE | APPROVED | eTRAKiT Inspection Request | 11/2/2020 11:26:05 AM
11/2/2020 11:26 AM MELO CONSTRUCTION INC
Insulation inspection
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
|
|
11/03/2020 | WALL INSULATION | DEREK POE | APPROVED | | |
|
11/09/2020 | DRYWALL NAIL - 1ST LAYER | DEREK POE | CORRECTION NOTICE | eTRAKiT Inspection Request | 11/6/2020 12:54:48 PM
11/6/2020 12:54 PM MELO CONSTRUCTION INC
Sheet rock & nail
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
11/9/2020 11:48:53 AM
1. Extend 5/8 drywall on garage side up to bottom of roof.
|
|
01/11/2021 | ROUGH ELECTRICAL | DEREK POE | PARTIAL APPROVAL | eTRAKiT Inspection Request | 1/8/2021 11:18:40 AM
1/8/2021 11:18 AM MELO CONSTRUCTION INC
Inspection is for all rought
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
1/12/2021 7:23:58 AM
Framing, electrical, and mechanical for new bedroom approved.
|
|
01/12/2021 | WALL INSULATION | DEREK POE | APPROVED | eTRAKiT Inspection Request | 1/11/2021 4:01:20 PM
1/11/2021 4:01 PM MELO CONSTRUCTION INC
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
1/12/2021 9:39:29 AM
Wall insulation for bedroom approved
|
|
01/14/2021 | DRYWALL NAIL - 1ST LAYER | DEREK POE | APPROVED | eTRAKiT Inspection Request | 1/13/2021 12:08:50 PM
1/13/2021 12:08 PM MELO CONSTRUCTION INC
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
|
|
03/31/2021 | ROUGH PLUMBING | JAMES ALLISON | CORRECTION NOTICE | eTRAKiT Inspection Request | 3/26/2021 1:57:46 PM
3/26/2021 1:57 PM MELO CONSTRUCTION INC
Inspection for ALL rough in master bathroom
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
3/31/2021 3:42:48 PM
At master bedroom and bathroom all roughs are complete. Ok to insulate.
At underfloor plumbing a drain from the shower, sink, and laundry collect into a 2" drain line and exit the front of the house next to the 4" main drain and is capped. The contractor explained he talked to the city of Tracy and they would allow them to install a alternative nonpotable reclaimed water system to catch grey water from these drains.
Per the records no such confirmation or review of this system has been conducted.
Connect drains to main drain and test, or provide a design from a registered designed professional who demonstrates competency to design the alternate water source system per section 1501.2 of the CPC.
If alternate system is to be used, change the scope of work to include this plumbing modification. Also, provide a plan showing the design and specs for all equipment to be used.
See chapter 15 of the California plumbing code for all requirements, testing, and inspections needed for this system. See section 1503.1.1 for clothes washer systems.
|
|
04/01/2021 | WALL INSULATION | JAMES ALLISON | APPROVED | eTRAKiT Inspection Request | 3/31/2021 11:39:37 AM
3/31/2021 11:39 AM MELO CONSTRUCTION INC
Wall and ceiling
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
|
|
04/02/2021 | DRYWALL NAIL - 1ST LAYER | JAMES ALLISON | APPROVED | eTRAKiT Inspection Request | 4/2/2021 12:29:10 PM
4/2/2021 12:29 PM MELO CONSTRUCTION INC
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
|
|
04/29/2021 | SHOWER PAN | RAMON VALENCIA | APPROVED | eTRAKiT Inspection Request | 4/28/2021 7:30:08 PM
4/28/2021 7:30 PM MELO CONSTRUCTION INC
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
|
|
06/16/2021 | FINAL BUILDING** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/15/2021 1:26:38 PM
6/15/2021 1:26 PM MELO CONSTRUCTION INC
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
6/17/2021 11:07:22 AM
1. Dishwasher gfci not operating / wrong location
2. Verify ceiling fan boxes
3. Seal all plumbing penetrations between the garage and dwelling
4. Shower door not installed
|
|
06/23/2021 | FINAL BUILDING** | JAMES ALLISON | APPROVED | eTRAKiT Inspection Request | 6/22/2021 4:34:29 PM
6/22/2021 4:34 PM MELO CONSTRUCTION INC
Contact Name: MELO CONSTRUCTION INC
Site Address: 389 W 23RD ST
Phone: 2098357314
e-Mail: melo.construction@sbcglobal.net
6/23/2021 8:46:54 AM
All previous corrections complete.
As an advisory, I told homeowner and contractor that existing door between the garage and living room shall be self-closing and self-latching and have a rating marked on the side.
Co collected
|
|
06/23/2021 | FINAL PLUMBING** | JAMES ALLISON | APPROVED | | |
|
06/23/2021 | FINAL ELECTRICAL** | JAMES ALLISON | APPROVED | | |
|
06/23/2021 | FINAL MECHANICAL** | JAMES ALLISON | APPROVED | | |
|