12/16/2020 | UNDERGROUND PLUMBING | TIM NAKASHIMA | APPROVED | eTRAKiT Inspection Request | 12/15/2020 8:43:02 PM
12/15/2020 8:42 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
12/16/2020 | UNDERGROUND ELECTRICAL | TIM NAKASHIMA | APPROVED | eTRAKiT Inspection Request | 12/15/2020 8:43:02 PM
12/15/2020 8:42 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
12/16/2020 | FOOTINGS / PIERS | TIM NAKASHIMA | APPROVED | eTRAKiT Inspection Request | 12/15/2020 8:43:01 PM
12/15/2020 8:42 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
12/16/2020 | UFER GROUND | TIM NAKASHIMA | APPROVED | | |
|
12/21/2020 | SLAB | TIM NAKASHIMA | APPROVED | eTRAKiT Inspection Request | 12/18/2020 1:30:55 PM
12/18/2020 1:30 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
01/14/2021 | FLOOR DIAPHRAGM | DEREK POE | APPROVED | eTRAKiT Inspection Request | 1/13/2021 3:50:40 PM
1/13/2021 3:50 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
12/16/2020 | SETBACKS | TIM NAKASHIMA | APPROVED | eTRAKiT Inspection Request | 12/15/2020 8:43:01 PM
12/15/2020 8:42 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
| ELECTRIC SERVICE | | | eTRAKiT Inspection Request | 1/31/2021 9:01:45 PM
1/31/2021 9:01 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
02/01/2021 | ELECTRIC SERVICE | DEREK POE | APPROVED | eTRAKiT Inspection Request | 1/31/2021 9:01:16 PM
1/31/2021 9:01 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
02/05/2021 | ROOF NAIL/DIAPHRAGM | DEREK POE | CANCELLED | eTRAKiT Inspection Request | 2/4/2021 12:40:40 PM
2/4/2021 12:40 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
02/05/2021 | EXTERIOR SHEAR | DEREK POE | CANCELLED | eTRAKiT Inspection Request | 2/4/2021 12:40:40 PM
2/4/2021 12:40 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
02/05/2021 | INTERIOR SHEAR | DEREK POE | CANCELLED | eTRAKiT Inspection Request | 2/4/2021 12:40:40 PM
2/4/2021 12:40 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
02/08/2021 | ROOF NAIL/DIAPHRAGM | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 2/7/2021 9:16:48 PM
2/7/2021 9:16 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
02/08/2021 | INTERIOR SHEAR | WLADYSLAW GROBELNY | NOT READY | eTRAKiT Inspection Request | 2/7/2021 9:16:48 PM
2/7/2021 9:16 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
02/08/2021 | EXTERIOR SHEAR | WLADYSLAW GROBELNY | PARTIAL APPROVAL | eTRAKiT Inspection Request | 2/7/2021 9:16:48 PM
2/7/2021 9:16 PM WOODSIDE HOMES
Contact Name: WOODSIDE HOMES
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
2/8/2021 9:10:00 PM
1.PROVIDE THE INFORMATION OF THE P.T. MUDSILL, VERIFY IF ZINC BORATE TREATED LUMBER WAS USED TO KEEP EXISTING STEEL,NOT GALVANIZED 3x3 PLATES
2. INSTAL TITEN A.B. TO COMPLY WITH THE SPACING SCHEDULE
|
|
03/15/2021 | ROUGH PLUMBING | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 3/14/2021 9:18:42 PM
3/14/2021 9:18 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
3/15/2021 10:09:31 PM
1. INSTALL STRAP ON ABS VENT - MASTER SHOWER VENT,LAUNDRY SINK VENT
2. INSTALL PROTECTIVE PLATE FOR ABS PIPES IN LR, FIRE SPRINKLER PIPE AT THE FIRE SPRINKLER GUAGE BOX
3. NEGATIVE SLOPE DWV ABOVE THE KITCHEN AND LR-ENTRANCE
|
|
03/15/2021 | ROUGH FRAME | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 3/14/2021 9:18:42 PM
3/14/2021 9:18 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
3/15/2021 10:09:37 PM
1. INSTALL ANCHOR BOLT AT MUD SILL SPLICE AT FRONT LOW WINDOW
|
|
03/15/2021 | ROUGH ELECTRICAL | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 3/14/2021 9:18:41 PM
3/14/2021 9:18 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
3/15/2021 10:09:40 PM
1. INSTALL LARGER PROTECTIVE PLATE FOR 5 ROMEX WIRES IN THE MASTER BATH
2. FIRE SPRINKLER WIRE ROMEX IN FLEXIBLE METAL CONDUIT HAS NO WIRE CONNECTOR
3. LR PANCAKE BOX NOT GROUNDED
4. IT BOX - INSTALL GROUND WIRE INSIDE THE BOX, SHEATHING TOO SHORT
5. FAN NOT CONNECTED IN THE MASTER TOILET ROOM
|
|
03/15/2021 | RESIDENTIAL FIRE SPRINKLER HYDRO | WLADYSLAW GROBELNY | CANCELLED | eTRAKiT Inspection Request | 3/14/2021 9:18:41 PM
3/14/2021 9:18 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
03/15/2021 | FIRE SPRINKLER ROUGH | WLADYSLAW GROBELNY | CANCELLED | eTRAKiT Inspection Request | 3/14/2021 9:18:41 PM
3/14/2021 9:18 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
03/16/2021 | ROUGH FRAME | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 3/15/2021 9:06:14 PM
3/15/2021 9:06 PM WOODSIDE 05N LP DBA
Corrections
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
3/16/2021 11:11:54 PM
1. INSTALL ANCHOR BOLT AT MUD SILL SPLICE AT FRONT LOW WINDOW - CORRECTION NOT MADE
|
|
03/16/2021 | ROUGH MECHANICAL | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 3/14/2021 9:18:42 PM
3/14/2021 9:18 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
3/15/2021 10:09:34 PM
1. INSTALL PROTECTIVE PLATES FOR AC LINE
2. INSTALL ALUMINUM-TAPE AT DRYER VENT
3. DRYER VENT LONGER THAN 14FT
3/16/2021 11:12:32 PM
BLACK HEATING DUCT TAPE USED FOR THE CONNECTIONS OF DRYER VENTS AND BATHROOM FANS, USE METAL ALUMINUM TAPE
|
|
03/16/2021 | FIRE SPRINKLER ROUGH | WLADYSLAW GROBELNY | APPROVED | | |
|
03/16/2021 | RESIDENTIAL FIRE SPRINKLER HYDRO | WLADYSLAW GROBELNY | APPROVED | | |
|
| ROUGH FRAME | | | eTRAKiT Inspection Request | 3/17/2021 4:22:39 AM
3/17/2021 4:22 AM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
| ROUGH PLUMBING | | | eTRAKiT Inspection Request | 3/17/2021 4:22:39 AM
3/17/2021 4:22 AM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
| ROUGH MECHANICAL | | | eTRAKiT Inspection Request | 3/17/2021 4:22:39 AM
3/17/2021 4:22 AM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
| RESIDENTIAL FIRE SPRINKLER HYDRO | | | eTRAKiT Inspection Request | 3/17/2021 4:22:38 AM
3/17/2021 4:22 AM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
| FIRE SPRINKLER ROUGH | | | eTRAKiT Inspection Request | 3/17/2021 4:22:38 AM
3/17/2021 4:22 AM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
03/17/2021 | ROUGH PLUMBING | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 3/17/2021 4:31:23 AM
3/17/2021 4:31 AM WOODSIDE 05N LP DBA
corrections
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
03/17/2021 | ROUGH ELECTRICAL | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 3/17/2021 4:22:39 AM
3/17/2021 4:22 AM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
03/23/2021 | WALL INSULATION | WLADYSLAW GROBELNY | ROLL OVER | eTRAKiT Inspection Request | 3/22/2021 9:20:14 PM
3/22/2021 9:20 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
03/23/2021 | CEILING INSULATION | WLADYSLAW GROBELNY | ROLL OVER | eTRAKiT Inspection Request | 3/22/2021 9:20:14 PM
3/22/2021 9:20 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
03/25/2021 | WALL INSULATION | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | |
|
03/25/2021 | CEILING INSULATION | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | |
|
04/05/2021 | ROUGH MECHANICAL | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 4/4/2021 10:36:14 PM
4/4/2021 10:36 PM WOODSIDE 05N LP DBA
Corrections
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
04/05/2021 | ROUGH FRAME | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 4/4/2021 10:36:14 PM
4/4/2021 10:36 PM WOODSIDE 05N LP DBA
Corrections
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
04/12/2021 | LATH | WLADYSLAW GROBELNY | ROLL OVER | eTRAKiT Inspection Request | 4/9/2021 12:02:53 PM
4/9/2021 12:02 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166056374
e-Mail: Edward.shipley@woodsidehomes.com
|
|
04/13/2021 | LATH | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | |
|
| DRYWALL NAIL - 1ST LAYER | | | | |
|
04/16/2021 | LATH | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 4/15/2021 2:08:05 PM
4/15/2021 2:08 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
|
|
04/16/2021 | GAS TEST | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 4/15/2021 2:08:05 PM
4/15/2021 2:08 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
4/16/2021 9:34:29 PM
Gas test 10 psi 15 min holding
4/19/2021 7:09:55 AM
Gas test 10 psi 15 min holding
|
|
04/16/2021 | DRYWALL NAIL - 1ST LAYER | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 4/15/2021 2:08:05 PM
4/15/2021 2:08 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
|
|
05/07/2021 | GAS SERVICE | RAMON VALENCIA | APPROVED | | |
|
06/03/2021 | FINAL SOLAR** | WLADYSLAW GROBELNY | CANCELLED | eTRAKiT Inspection Request | 6/2/2021 12:17:09 PM
6/2/2021 12:17 PM WOODSIDE 05N LP DBA
Contact Name: Martin Short
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 2094995013
e-Mail: martin.short@woodsidehomes.com
|
|
06/03/2021 | FINAL ROOF** | WLADYSLAW GROBELNY | ROLL OVER | eTRAKiT Inspection Request | 6/2/2021 12:17:09 PM
6/2/2021 12:17 PM WOODSIDE 05N LP DBA
Contact Name: Martin Short
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 2094995013
e-Mail: martin.short@woodsidehomes.com
|
|
06/04/2021 | FINAL SOLAR** | RAMON VALENCIA | NO ACCESS | | |
|
06/04/2021 | FINAL ROOF** | RAMON VALENCIA | NO ACCESS | | |
|
06/07/2021 | FINAL ROOF** | WLADYSLAW GROBELNY | NOT READY | eTRAKiT Inspection Request | |
|
06/07/2021 | FINAL SOLAR** | WLADYSLAW GROBELNY | NOT READY | eTRAKiT Inspection Request | 6/4/2021 1:54:04 PM
6/4/2021 1:54 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
|
|
06/07/2021 | FINAL ROOF** | WLADYSLAW GROBELNY | CANCELLED | eTRAKiT Inspection Request | 6/4/2021 1:54:04 PM
6/4/2021 1:54 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
6/7/2021 2:10:18 PM
Duplicate inspection scheduled
|
|
06/07/2021 | FINAL PLUMBING** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/4/2021 1:54:04 PM
6/4/2021 1:54 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
6/7/2021 3:18:44 PM
Garbage disposal hose kinked
|
|
06/07/2021 | FINAL MECHANICAL** | WLADYSLAW GROBELNY | PARTIAL APPROVAL | eTRAKiT Inspection Request | 6/4/2021 1:54:04 PM
6/4/2021 1:54 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
6/7/2021 3:18:46 PM
Furnace roof vents not verified
|
|
06/07/2021 | FINAL HVAC** | WLADYSLAW GROBELNY | PARTIAL APPROVAL | eTRAKiT Inspection Request | 6/4/2021 1:54:04 PM
6/4/2021 1:54 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
6/7/2021 3:18:48 PM
Furnace roof vents not verified
|
|
06/07/2021 | FINAL ELECTRICAL** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/4/2021 1:54:04 PM
6/4/2021 1:54 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
6/7/2021 3:18:50 PM
1. Garbage disposal/ no switch
2. Vacuum the electrical panels to remove drywall dust and other foreign objects
|
|
06/07/2021 | FINAL BUILDING** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/4/2021 1:54:04 PM
6/4/2021 1:54 PM WOODSIDE 05N LP DBA
Contact Name: Hector Barragan
Site Address: 111 woodmere road
Phone: 2095950976
e-Mail: hectorb@woodsidehomes.com
6/7/2021 3:18:53 PM
1. Seal marble under the shower seating
2. Seal the plumbing penetrations in the laundry for future sink, garage gas pipe for the water heater
3. Not all trades approved
|
|
06/08/2021 | FINAL PLUMBING** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/7/2021 4:03:20 PM
6/7/2021 4:03 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166089600
e-Mail: jose.garcia@woodsidehomes.com
6/8/2021 4:32:42 PM
Paint abs drain on exterior,front, laundry pan
|
|
06/08/2021 | FINAL MECHANICAL** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/7/2021 4:03:20 PM
6/7/2021 4:03 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166089600
e-Mail: jose.garcia@woodsidehomes.com
6/8/2021 4:32:44 PM
1. Exhaust and intake vent for the furnace reversed
|
|
06/08/2021 | FINAL HVAC** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/7/2021 4:03:20 PM
6/7/2021 4:03 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166089600
e-Mail: jose.garcia@woodsidehomes.com
6/8/2021 4:32:47 PM
1. Exhaust and intake vent for the furnace reversed
|
|
06/08/2021 | FINAL ELECTRICAL** | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 6/7/2021 4:03:19 PM
6/7/2021 4:03 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166089600
e-Mail: jose.garcia@woodsidehomes.com
|
|
06/08/2021 | FINAL BUILDING** | WLADYSLAW GROBELNY | CORRECTION NOTICE | eTRAKiT Inspection Request | 6/7/2021 4:03:19 PM
6/7/2021 4:03 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166089600
e-Mail: jose.garcia@woodsidehomes.com
6/8/2021 4:32:52 PM
1. Not all trades approved
2. Shower door in master shower not installed
|
|
06/08/2021 | FINAL SOLAR** | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 6/7/2021 3:53:40 PM
6/7/2021 3:53 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166089600
e-Mail: jose.garcia@woodsidehomes.com
|
|
06/08/2021 | FINAL ROOF** | WLADYSLAW GROBELNY | APPROVED | eTRAKiT Inspection Request | 6/7/2021 3:53:40 PM
6/7/2021 3:53 PM WOODSIDE 05N LP DBA
Contact Name: WOODSIDE 05N LP DBA
Site Address: 2549 CORDELIA LANE LOT 49
Phone: 9166089600
e-Mail: jose.garcia@woodsidehomes.com
|
|